1.Pressure switch failure.--- (Measure the pressure swi […]

1.Pressure switch failure.--- (Measure the pressure switch contacts are normal)
2. Load solenoid valve failure. ---(Remove the load solenoid valve maintenance and repair)
3. Blowing valve is damaged.--- (Remove the blow valve repair, if damaged, updated.)
4. Pressure switch working pressure is set too high. ---(Lower the pressure of the pressure switch.)
5. Intake valve failure. ---(Remove the inlet valve and repair if it is damaged.)
6. Pressure sensor failure.-- -(Make pressure transmitter calibration, update if it is damaged.)
7. Pressure gauge error ---(pressure gauge replacement)